Four E’s Scientific TVK096 PCR Temperature Verification Kit for 96-Well
The Four E’s Scientific TVK096 Temperature Verification Kit is a precision instrument qualification accessory designed for the performance verification and qualification of 96-well PCR thermocyclers. Specifically compatible with the Four E’s Scientific Optima 096 Gradient PCR thermocycler, the TVK096 enables laboratories to verify block temperature accuracy and uniformity as part of instrument qualification, GLP compliance, and ongoing performance monitoring programmes.
In regulated laboratory environments such as pharmaceutical QC, GLP-compliant research facilities, and accredited testing laboratories, periodic temperature verification of PCR thermocyclers is a critical requirement for ensuring that amplification conditions are operating within validated parameters. The TVK096 provides the measurement capability required to satisfy these documentation and compliance requirements.
Key Features
Wide Measuring Range — 0°C to 105°C
The TVK096 covers a measuring range of 0°C–105°C, encompassing the full operational temperature range of the Optima 096 thermocycler and all standard PCR protocol temperatures including denaturation (up to 98°C), annealing, and extension steps.
High Temperature Accuracy — ±0.1°C
A temperature accuracy of ±0.1°C ensures that block temperature verification measurements are sufficiently precise to detect deviations from validated temperature parameters — providing confidence in the accuracy of amplification conditions and supporting instrument qualification documentation.
Excellent Sensor Uniformity — 0.1°C
A sensor uniformity of 0.1°C across the measurement array ensures consistent and comparable temperature readings across all measurement positions — enabling comprehensive block uniformity assessment as part of thermocycler qualification protocols.
Regulatory Compliance Support
The TVK096 supports thermocycler temperature verification as required under GLP, ISO, and pharmaceutical regulatory frameworks — providing the measurement data needed for instrument qualification records, periodic performance review documentation, and regulatory submission support.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | TVK096 |
| Part Number | TVK096 |
| Measuring Range | 0°C–105°C |
| Temperature Accuracy | ±0.1°C |
| Sensor Uniformity | 0.1°C |
| Compatibility | Four E’s Scientific Optima 096 Gradient PCR (PR122) |
Applications
- PCR thermocycler qualification — installation qualification (IQ), operational qualification (OQ), and performance qualification (PQ) of 96-well PCR thermocyclers
- GLP compliance — temperature verification documentation for GLP-compliant laboratory environments
- Pharmaceutical quality assurance — periodic thermocycler performance monitoring in pharmaceutical research and QC laboratories
- Accredited laboratory compliance — instrument performance verification for ISO and accreditation body requirements
Availability in Ireland
The Four E’s Scientific TVK096 Temperature Verification Kit is available from Varen Scientific — Ireland’s authorised distributor for Four E’s Scientific laboratory instruments. We provide local procurement support, clear lead-time communication, and documentation assistance for Irish pharmaceutical and regulated laboratories sourcing instrument qualification accessories.
For further information on PCR thermocycler qualification requirements in regulated laboratory environments, refer to guidance published by the Health Products Regulatory Authority (HPRA).
To request a quote, contact our team or use the Request a Quote button above.